• Products & Solutions
  • Insights & Support
  • About
  • Contact

Measurement solutions for your power integrity needs

Picotest products are designed to simplify measurements while providing the ultimate resolution using your test instruments. This allows the optimum use of your instruments, maximizing their value.

View all Products

Product Types

  • New Releases
  • Best Sellers
  • DC Blockss
  • Ground Loop Isolatorss
  • Injectors
  • Load Stepperss
  • Vector Network Analyzers
  • PDN Cables
  • Probes
  • Publications
  • Source Power Amps
  • Software
  • Test Boards
  • Training
  • Benchtop Instruments

Test Types

  • 1-Port and 2-Port Impedance/Ripple
  • 3-Port Impedance
  • Component Test
  • Converter Input Impedance
  • EMI/EMC Probes
  • Miscellaneous
  • Noise
  • Protection Devices
  • PSRR, PSNR, PSMR – Line Injectors
  • Stability – Gain/Phase
  • TDR
  • Training
  • Transient Step Load

Solutions

  • PDN Measurement for Power Integrity
  • TDR/TDT
  • Tektronix
  • Power Supply Rejection Ratio Measurement
  • Non-invasive Stability Measurement
  • Ultra-low Impedance
  • Rohde & Schwarz
  • Inductor Measurement Including DC Bias
  • Input Impedance Measurement for DC-DC Converters

Training: Master the Fundamentals of Power Integrity and Power Supply Testing

This course is now available on-demand and covers how to master the most important power supply measurements including those associated with Power Integrity and today?s power distribution systems.

The topics and tests are discussed in detail with a variety of lab demonstrations.

Learn more

Insights

  • All Insights
  • Component Test
  • FAQs
  • GaN
  • Impedance
  • Noise/EMI/EMC
  • Power Integrity
  • Probes
  • PSRR/PSNR/PSMR
  • Stability
  • Training
  • Transient Load Step

Support

  • NISM
  • Injectors/TDR
  • Probes/Amps
  • Bode 100/500 VNA
  • Power Supplies
  • M3500A/M3510A
  • G5100A
  • U6200A
  • Setup Files
  • Home
  • Products
  • Solutions
  • Insights
  • Support
  • About Us
  • Contact Us

FAQ #19: What is the difference between a Frequency Response Analyzer (FRA) and a Vector Network Analyzer (VNA)?

What is the difference between a Frequency Response Analyzer (FRA) and a Vector Network Analyzer (VNA)?

The FRA is generally designed to measure Bode plots of electronic circuits such as amplifiers or filters. A special application of an FRA is to measure Bode plots of control systems, such as voltage regulators and power converters. FRAs generally offer two high impedance inputs, compatible with oscilloscope probes and an oscillator output port. Some units also offer 50 Ohm input settings in addition to the high impedance inputs. The FRA does not generally include measurement calibration to remove the frequency dependent characteristics of the probes and interconnects to the Device Under Test (DUT).

Both the VNA and the FRA can measure complex magnitude and phase values over frequency.

The VNA, on the other hand, only has two ports that serve as inputs and outputs and the oscillator is not a separated output. The VNA is designed primarily to measure scatter parameters, generally referred to as S-parameters. S-parameters are used to define the response of a system with respect to its “ports” where each port is either an input or an output. The simplest s-matrix has only one port, which would represent a component connected to ground, since ground is not counted as a port. A filter, on the other hand, is generally a 2 port device, with one port being the input and one port being the output. These measurements include reflection, admittance and gain.

The VNA inputs are typically only 50 Ohms and offer measurement calibrations routines for thru calibration and a minimum of Short Open Load (“SOL”) calibration, though some also include a propagation delay calibration. The thru calibration calibrates the gain of the measurement system, including the interconnects, but without the DUT installed. For example, measuring a filter uses two cables to connect the input and output to the VNA. The THRU calibration is performed with the filter removed and the two cables connected together. This calibrates the measurement to 0dB and 0 Degrees without the filter installed.

There are three ways to measure impedance with a VNA. One method is to place the DUT between 2 ports; another method is to place the DUT as a shunt to ground with both ports connected to the DUT. The first method is better for high impedance measurements while the second method is better for low impedance measurements. The single port reflection method uses only one port and is most accurate for impedances that are close to 50 Ohms. The impedance is calibrated using an SOL calibration routine, which calibrates the OPEN circuit (to remove parasitic capacitance), Short, to remove the interconnect impedance and Load, which is used to calibrate precisely to 50 Ohms. Some VNAs also include a propagation delay calibration, which removes the effective inductance related to the propagation of the signal through a short that is physically identical in dimension to the DUT.

The VNA typically offers many more measurement options than an FRA and the VNA also generally offers a much higher maximum frequency capability. The VNA is generally more expensive than the FRA for these reasons.

The OMICRON Lab Bode 100 offers all of the aforementioned features and benefits of BOTH the FRA and the VNA, with the exception that the cost of the Bode 100 is lower than most other FRAs or VNAs.

The configuration screen below shows that the oscillator is a 50 Ohm port, which can be directly connected internally to CH1 (Port 1) as it would be in a traditional VNA. CH1 and CH2 (Port 2) can each be set to either high impedance (oscilloscope probe compatible) or to 50 Ohms as in most VNAs.

OMICRON Lab Bode 100 Configuration Screen

The Bode 100 supports both thru gain calibration and SOL impedance calibration. The Bode 100 also offers two calibration algorithms (user & probe calibration) for each of these calibration methods.

The Probe calibration is performed at factory defined frequencies and correction factors for the actual measurement frequencies are calculated by linear interpolation. The User calibration, measures the correction factors for every measured frequency to ensure highest accuracy.

OMICRON Lab Bode 100 Calibration Window

The Bode 100 supports all of the FRA and VNA measurements, including Gain, Reflectance, Admittance and Impedance.

While all of these are necessary for power supply design, many are also especially useful for high speed systems, which require Signal Integrity (SI), Power Integrity (PI) or Power Distribution Network (PDN) measurements.

OMICRON Lab Bode 100 Measurements

The Bode 100 includes all of the popular display graphics for both the FRA and the VNA.  The FRA screen shows the typical displays of gain, phase, polar, real and imaginary plots while in the S-parameter screen offers typical VNA measurements such as VSWR, Smith charts, etc.

Bode 100 Measurements

Impedance mode includes all of the typical displays of a full featured Impedance Analyzer, including real, imaginary, capacitance, inductance, resistance and Q in both rectangular and polar formats.

Bode 100 Measurements

In summary, if you only want to measure the control loop of a power supply or a simple transfer function, then an FRA may meet all of your needs.  If you want to measure impedances, PDNs and component parameters or parasitics, a VNA offers many more features that support those more complex measurements.

Related Products

Bode 500 VNA

Bode 500 VNA

Read more: Bode 500 VNA
Bode 100 VNA

Bode 100 VNA

Read more: Bode 100 VNA

Insights Categories

  • All (221)
  • Books (1)
  • Component Test (4)
  • FAQs (16)
  • GaN (3)
  • Impedance (32)
  • NISM (3)
  • Noise/EMI/EMC (4)
  • Power Integrity (37)
  • Probes (6)
  • PSRR/PSNR/PSMR (7)
  • Stability (9)
  • TDR (3)
  • Training (2)
  • Transient Load Step (18)

Featured Insights

Calibration, Embedding & De-Embedding – Achieving Highly Accurate Impedance Results

OMICRON Lab hosted their 14th Power Analysis & Design Symposium – April 9th, 2025 Watch Steve Sandler discussing how to achieve Highly Accurate Impedance…

Read more: Calibration, Embedding & De-Embedding – Achieving Highly Accurate Impedance Results

PSRR Testing with the J2120A Line Injector

Dealing with Line Injection Issues Here is information on the Power Supply Rejection Ratio (‘PSRR’) measurement setup using the J2120A line injector. Depending on…

Read more: PSRR Testing with the J2120A Line Injector

Related Insights

Dynamic Load Stepping: A New Way to Test Power Rails for GPUs and ASICs

Achieving Better Energy Efficiency in AI Data Centers With Power Integrity Testing

How To Measure 3-Port Impedance with Picotest Products

Calibration with De-Embedding for Precise Component Measurements | Signal Integrity Journal

How to Simulate Low Voltage, High Power 2000 Amps to a Dynamic Digital Load

Links

  • Home
  • About Us
  • Contact Us
  • e: info@picotest.com
  • t: 877-914-7426
  • f: 877-914-7416
  • a: U.S. Home Office, Picotest Phoenix, AZ 85085

Product Type

  • New Releases
  • Best Sellers
  • DC Blocks
  • Ground Loop Isolators
  • Injectors
  • Load Steppers
  • Vector Network Analyzers
  • PDN Cables
  • Probes
  • Publications
  • Source Power Amps
  • Software
  • Test Boards
  • Training
  • Benchtop Instruments

Solutions

  • PDN Measurement for Power Integrity
  • TDR/TDT
  • Tektronix
  • Power Supply Rejection Ratio Measurement
  • Non-invasive Stability Measurement
  • Ultra-low Impedance
  • Rohde & Schwarz
  • Inductor Measurement Including DC Bias
  • Input Impedance Measurement for DC-DC Converters

Training & Resources

  • Insights
  • Support
  • Courses

Information

  • Warranty
  • Returns Policy
  • Shipping Policy
  • Privacy Policy
  • Terms & Conditions